Do you still need an HBA once your NAS case has a backplane? In most builds past six drives, yes, and the card is the easy part. The parts that strand people are the cable between the card and the backplane, the airflow the card expects, and the difference between a SAS backplane and a SATA one. A 9300-8i that arrives with the wrong breakout cable gives you eight empty bays and a return label.
This guide treats the HBA and backplane side of a DIY NAS as one buying decision. You will pick an LSI card (9207-8i, 9300-8i or 9400-16i), match its connectors to a SAS or SATA backplane, choose the right breakout cable, keep the card cool, and see how it all behaves under ZFS and TrueNAS. We rechecked every spec below against the Broadcom install guides and the 9300 and 9400 product briefs, and every listing against Amazon, in November 2026.
Quick picks for the HBA and backplane
If you only want the parts list, these are the picks. Each one has its own section further down with the trade-off we would warn a friend about.
- Best card for most builds: LSI 9300-8i in IT mode, eight 12Gb/s ports on two SFF-8643 connectors.
- Budget card for spinning disks: LSI 9207-8i in IT mode, sold with two SFF-8087 breakout cables.
- Sixteen drives without an expander: Broadcom 9400-16i, four SFF-8643 connectors.
- Cable for a SATA-port backplane: Cable Matters SFF-8643 forward breakout.
- Cable for a Mini-SAS HD backplane: 10Gtek SFF-8643 to SFF-8643, two in the pack.
- Card cooling: Noctua NF-A4x20 PWM on the heatsink.
- Case with the backplane built in: SilverStone CS382, eight hot-swap bays.
Already settled on a card and only need the cable? Skip to the forward and reverse breakout table in the buying section, because that is the part people get wrong most often. If you still need to choose the card itself across more options, our HBA card ranking for TrueNAS also covers the 9211-8i, the PCIe 4.0 tri-mode 9500-8i and a SAS expander card.
How we picked these parts
Every spec in this guide comes from the maker. The 9207-8i figures are from the Broadcom user guide for that card, the 9300-8i figures from its quick installation guide and the SAS 9300 product brief, and the 9400-16i figures from the Broadcom 9400 series product brief. Cable, fan and case specs come from the Cable Matters, 10Gtek, Noctua and SilverStone product pages. Prices and stock come from the Amazon catalog on the day we checked, and we quote them as bands because HBA listings move every week.
We left out cards that only ship with RAID firmware, listings titled “compatible with 9300-8i” that do not say which chip they carry, and anything sold with scarce stock. Almost every HBA on Amazon comes from a third-party reseller, and clone boards do circulate, so we only picked listings that name the chip and firmware, and we name the seller where it matters. The fan and the cables are the boring parts of the build, but they decide whether the card ever sees your drives.
LSI 9207-8i vs 9300-8i vs 9400-16i at a glance
The three cards differ on four things that change a build: link speed, connector type, port count and how much heat they make. Read the connector column first, because it decides the cable you order.
| Card | Controller | Host bus | Drive ports | Connectors | Power | Airflow spec | Price band |
|---|---|---|---|---|---|---|---|
| LSI 9207-8i | SAS2308 | PCIe 3.0 x8 | 8 at 6Gb/s | 2x SFF-8087 | 9.8 W nominal | 200 LFM | about $55 to $60 |
| LSI 9300-8i | SAS3008 | PCIe 3.0 x8 | 8 at 12Gb/s | 2x SFF-8643 | 13 W nominal | 200 LFM | about $55 to $65 |
| Broadcom 9400-16i | SAS3416 | PCIe 3.1 x8 | 16 at 12Gb/s, tri-mode | 4x SFF-8643 | 11.95 W typical | 200 LFM | about $175 to $190 |
The 9300-8i power and airflow figures come from the Broadcom SAS 9300 product brief, which also lists 1024 non-RAID devices and a 3-year warranty. All three cards share one requirement you will not find on the box: 200 linear feet per minute of air across the heatsink, which is server airflow, not desktop case airflow.
1. LSI 9300-8i: the default card for an 8-bay backplane
The 9300-8i is the card we would put in almost every 4 to 8 bay TrueNAS or Unraid box. It runs eight drives at up to 12Gb/s SAS or 6Gb/s SATA through two SFF-8643 (Mini-SAS HD) connectors, and it needs an x8 PCIe slot, as the Broadcom quick installation guide states.
Mini-SAS HD is the reason this card wins over the cheaper 9207-8i. Almost every backplane and breakout cable sold today uses SFF-8643, so the 9300-8i works with a standard SFF-8643 cable or breakout for a SilverStone CS382, a Supermicro direct-attach backplane or loose drives, with no hybrid SFF-8087 cable to hunt down. The extra link speed matters less than people think for hard drives, but it does matter once you mix in SATA SSDs for a special vdev or an all-flash pool.
- Good fit: any 4 to 8 bay ZFS build, or a 12 bay build behind an expander backplane.
- Skip it if you need more than eight direct-attached drives, or your board only has an x4 slot (Broadcom specifies an x8 slot).
Our linked listing is sold by KCMconmey and titled as an IT-mode 9300-8i with two SFF-8643 ports, at about $55 to $65 when we checked (check the live price on Amazon). It ships without cables, so add two forward breakouts or two SFF-8643 cables depending on your backplane, which we cover in picks 4 and 5.
2. LSI 9207-8i: the cheap SAS2308 card for an all-HDD pool
The 9207-8i is the oldest card here and still a sensible one for an all-HDD pool. The Broadcom user guide lists the SAS2308 controller, eight PCIe 3.0 lanes, eight 6Gb/s SATA and SAS ports on two SFF-8087 connectors with sidebands, and support for up to 256 end devices.
A hard drive cannot saturate a 6Gb/s link, so for eight spinning disks the 9207-8i gives up nothing that you would measure. It also runs cooler than the SAS3 cards, at 9.8 W nominal and 16 W worst case per Broadcom, which helps in a quiet tower. The catch is the connector: SFF-8087 is the older Mini-SAS plug, so a modern SFF-8643 backplane needs an SFF-8087 to SFF-8643 cable instead of the usual one.
- Good fit: an all-HDD build fed by breakout cables, or an older server backplane that already uses SFF-8087.
- Skip it if you plan an SSD pool, or your backplane has SFF-8643 sockets and you would rather not hunt for hybrid cables.
For this card we link a YiBaoTong listing that names the SAS2308 chip, P20 IT firmware and includes two SFF-8087 to SATA breakouts in the box, at about $55 to $60 (check the live price on Amazon). With the cables included, it is the cheapest complete way to hang eight SATA drives off a ZFS box.
3. Broadcom 9400-16i: sixteen drives without an expander
Once a build passes eight bays, you choose between a second card, a SAS expander or a 16-port HBA. The 9400-16i is the 16-port answer. The Broadcom 9400 series product brief lists the SAS3416 controller on a PCIe 3.1 x8 host bus, four SFF-8643 connectors, 12Gb/s SAS and 6Gb/s SATA, and tri-mode support for up to four x4 NVMe drives attached directly.
One slot instead of two is the real reason to buy it. Consumer and workstation boards rarely have two spare x8 slots, and the 9400-16i draws a typical 11.95 W, less than two older cards together. It also avoids an expander, so every drive gets a dedicated lane to the controller, which the TrueNAS hardware guide calls the optimal layout when you can manage it.
- Good fit: 12 to 16 bay builds on a board with one spare x8 slot.
- Skip it if eight drives are enough, because it costs about three times a 9300-8i, or you want PCIe 4.0 NVMe, where the 9500 series fits better.
We link the retail Broadcom part 05-50008-00 sold by SCSI4ME, at about $175 to $190 (check the live price on Amazon). It needs four cables, one per SFF-8643 port, so budget for those as well.
4. Cable Matters SFF-8643 forward breakout: wiring a SATA backplane
A forward breakout runs from one Mini-SAS HD port on the HBA to four SATA plugs. Use it for loose drives, for a hot-swap cage with SATA ports, or for a backplane like the one in the CS382 that takes eight SATA 7-pin cables. Two of them turn a 9300-8i into eight drive connections.
Cable Matters lists it as SFF-8643 host to four SATA 7-pin, 1 m, rated up to 12Gbps with a compatible controller, and its product page states that it does not work from motherboard SATA ports to a SAS backplane. That line is the whole forward versus reverse problem in one sentence. If you mean to plug it into a 9207-8i, it will not fit, because that card uses SFF-8087.
- Good fit: a 9300-8i or 9400-16i feeding SATA-port backplanes, cages or bare drives.
- Skip it if your backplane has its own SFF-8643 sockets. Use pick 5 instead.
Expect about $20 (check the live price on Amazon). In a small case, look for a 0.5 m version, because a shorter cable is easier to route away from the CPU cooler and the heatsink on the card.
5. 10Gtek SFF-8643 to SFF-8643: wiring a Mini-SAS HD backplane
Server chassis and rack JBODs put SFF-8643 sockets on the backplane itself, one socket per four bays on a direct-attach board, or one or two sockets total on an expander board. Here you want a straight SFF-8643 to SFF-8643 cable, not a breakout.
The 10Gtek listing gives 12Gbps, 100 ohm, 30 AWG and sideband wiring, in 0.5 m, 0.8 m and 1 m lengths. The sideband matters on a backplane because it carries the SGPIO signals that drive the bay activity and fault LEDs, which the Broadcom guides list for both the 9207-8i and the SAS3 cards. Measure from the HBA slot to the backplane socket before you order, since a 0.5 m cable that falls short by a few centimetres is worse than a 1 m cable coiled behind the cage.
- Good fit: rackmount chassis, Supermicro-style backplanes and JBOD shelves with SFF-8643 inputs.
- Skip it if your card is a 9207-8i. Order an SFF-8087 host to SFF-8643 target cable instead.
A two-pack sells for about $17 to $20 (check the live price on Amazon), which covers a 9300-8i feeding an 8-bay direct-attach backplane.
6. Cable Matters SFF-8087 breakout: the cable for a 9207-8i
If your 9207-8i arrived without cables, or the bundled ones are too short for your case, this is the replacement. It runs from one SFF-8087 port to four SATA drives at 6Gbps per drive, forward only.
We link the 1 m (3.3 ft) version, and Cable Matters also sells a 0.5 m one. SFF-8087 is the older and bulkier Mini-SAS plug, so check that it clears any tall component beside the port on the card before you close the case. It is SATA only, so SAS drives need a SAS backplane or a breakout whose listing says it supports SAS drives.
- Good fit: 9207-8i and 9211-8i owners wiring bare SATA drives or a SATA-port cage.
- Skip it if you bought a card that ships with cables and they reach your drives.
Expect about $15 to $16 per cable (check the live price on Amazon).
7. Noctua NF-A4x20 PWM: cooling a card built for server airflow
Every card in this guide asks for 200 linear feet per minute of air over its heatsink. A 1U or 2U server delivers that with a wall of fans; a quiet tower with one rear 120 mm fan does not. A 40 mm fan on the HBA heatsink is the cheapest way to close that gap.
The Noctua spec sheet gives 40x40x20 mm, up to 5000 rpm, 9.4 cubic metres per hour (5.53 CFM) and 14.9 dB(A) at full speed, on a 12 V 4-pin PWM connector drawing 0.46 W. That is quiet enough for a NAS you keep in a living room. Plug it into a spare 4-pin fan header on the motherboard. Most HBA heatsinks have no screw holes for a fan, so plan on mounting it with two zip ties through the heatsink fins or on a slot bracket aimed at the card.
- Good fit: any HBA in a tower, mini-ITX or desktop NAS case.
- Skip it if a front intake fan already blows straight across the PCIe slots, as in many rackmount chassis.
Budget about $15 to $17 (check the live price on Amazon), which is cheap insurance on a card that sits between ZFS and every drive.
8. SilverStone CS382: an 8-bay case with the backplane built in
The CS382 is a Micro-ATX tower with eight hot-swap bays on a SAS 12G and SATA 6G backplane, plus room for three more internal drives. It is the case our TrueNAS ZFS storage server build uses for its eight-bay tower, and it shows how a backplane changes the cabling.

What you can easily miss is that the CS382 backplane takes eight SATA 7-pin cables, not SFF-8643. A footnote on the SilverStone product page says a Mini-SAS HD (SFF-8643) to SATA 7-pin cable and a 12Gb/s SAS card are required for 12Gb/s performance. So the right kit is a 9300-8i plus two forward breakouts from pick 4. You can also run the bays from motherboard SATA ports with plain SATA cables, but then SAS drives will not work and you lose the clean HBA pass-through to ZFS.
- Good fit: an 8-drive RAIDZ2 build on Micro-ATX or Mini-ITX with a standard ATX power supply.
- Skip it if you need full ATX or more than eight hot-swap bays, or a power supply deeper than its 180 mm limit.
Amazon had it at about $230 to $240 when we checked (check the live price on Amazon). For hot-swap bays you can add to an existing tower instead, see our hot-swap drive cage picks.
SAS vs SATA backplanes: what each one accepts
A SAS backplane accepts both SAS and SATA drives, while a SATA backplane or a motherboard SATA port accepts SATA drives only. The TrueNAS hardware guide puts it bluntly: “you cannot use a SAS drive in a port designed for SATA drives.” That matters to you if you shop used. Enterprise SAS drives are often the cheapest terabytes on eBay, and they are useless on a SATA-only path.
The other split is direct attach versus expander. A direct-attach backplane gives every bay its own lane, so an 8-bay board needs two SFF-8643 inputs and a 16-bay board needs four. An expander backplane puts a SAS switch chip on the board, so one or two inputs can serve 24 bays or more. TrueNAS notes that expanders mostly appear on backplanes with more than twelve bays and that they reach SATA disks through the SATA Tunneling Protocol. For a homelab, the practical rules look like this:
- Up to 8 bays: direct attach from one 8-port card.
- 9 to 16 bays: a 9400-16i, or two 8-port cards if you have the slots.
- Over 16 bays: an expander backplane, an expander card or an external JBOD enclosure behind one 8-port HBA.
- Used SAS drives anywhere in the plan: SAS backplane plus HBA, never motherboard ports.
Bandwidth rarely decides it. A PCIe 3.0 x8 slot carries about 7.9 GB/s, and even at a generous 300 MB/s per hard drive, eight drives need 2.4 GB/s. An expander is different, because every drive behind it shares the SAS cable to the HBA. One SFF-8643 cable carries four 12Gb/s lanes, about 4.8 GB/s, so 24 hard drives behind a 9300-8i want both cables run to the expander, while 24 SATA SSDs would be held back by the HBA link rather than the drives. If your board is short on slots, our PCIe lanes guide explains which slots are wired to the CPU and which share the chipset uplink.
Forward vs reverse breakout cables
Breakout cables are directional even though they look identical. A forward breakout goes from the Mini-SAS port on a controller to four drives or four SATA backplane ports. A reverse breakout goes the other way, from four SATA ports on a motherboard to one Mini-SAS socket on a backplane. Plug the wrong one in and the drives simply never appear. Match the cable to what is at each end:
| From | To | Cable to order |
|---|---|---|
| 9300-8i or 9400-16i (SFF-8643) | SATA drives or SATA-port backplane (CS382) | SFF-8643 to 4x SATA, forward |
| 9300-8i or 9400-16i (SFF-8643) | Backplane with SFF-8643 sockets | SFF-8643 to SFF-8643 |
| 9300-8i or 9400-16i (SFF-8643) | Older backplane with SFF-8087 sockets | SFF-8643 host to SFF-8087 target |
| 9207-8i (SFF-8087) | SATA drives or SATA-port backplane | SFF-8087 to 4x SATA, forward |
| 9207-8i (SFF-8087) | Backplane with SFF-8643 sockets | SFF-8087 host to SFF-8643 target |
| Motherboard SATA ports | Direct-attach backplane with SFF-8643 or SFF-8087 sockets (not an expander backplane) | 4x SATA to Mini-SAS, reverse |
Hybrid cables such as SFF-8643 to SFF-8087 are also directional, so read which end the listing calls host and which it calls target. Reverse breakouts are the hardest to find from a known brand. When we searched, most Amazon listings for them were unbranded. That is one more reason for you to put an HBA in front of a Mini-SAS backplane rather than wiring it from the motherboard.
IT mode and TrueNAS compatibility
ZFS wants to see each raw disk, its serial number and its SMART data, with no RAID layer in between. That is what IT (initiator target) firmware gives you on an LSI card. The TrueNAS hardware guide calls the 6 and 12 Gbps Broadcom (formerly LSI) SAS HBAs “the uncontested most popular storage controllers used with TrueNAS.” It tells you to flash “the latest IT or Target Mode firmware to disable the optional RAID functionality found in the IR firmware.”
Hardware RAID is worse than it sounds. The same guide lists what a RAID card can do to your pool. It can mask disk serial numbers and SMART health, run slower than the HBA equivalent, and lose data if a write cache runs on a dead battery backup unit. That is why every card above is an HBA sold in IT mode rather than a MegaRAID card. If a listing says IR, RAID or MegaRAID, keep scrolling. Should you buy a cheaper card and flash it yourself? Only if you enjoy it, because the IT-mode listings now cost about the same.
Driver support is not something you need to worry about for any of the three. TrueNAS SCALE uses the Linux mpt3sas driver, and its PCI ID table lists all three controllers. It also answers to the old mpt2sas name. TrueNAS also bundles the Broadcom sas2flash, sas3flash and storcli tools, so you can check the firmware from the TrueNAS shell after the card arrives. The drives you hang off it still matter more than the card, so pick from our NAS hard drive picks and avoid SMR models for ZFS, as our CMR vs SMR guide for NAS drives explains.
Cooling an HBA in a quiet NAS case
Broadcom rates all three cards for 0 to 55 °C with 200 LFM of airflow, the same figure in the 9207-8i user guide, the 9300 product brief and the 9400 product brief. Server chassis are designed around that number. A desktop case with slow fans can leave a passive HBA heatsink in still air, and the crossflashing guide on the TrueNAS forum warns that cards with small heatsinks can overheat without airflow, with some causing kernel panics. That is forum guidance, not a Broadcom spec, but it matches the airflow rating.
Three habits keep a card in range. Put the HBA in a slot that sits in the path of a front intake fan, not in the dead zone under a GPU or behind the drive cage. Add a 40 mm fan to the heatsink if the case has no fan blowing across the slots. Keep the breakout cables bundled and routed along the case floor, because a loose loom over the card blocks what little air it gets. On a 16-bay build, choosing a single 9400-16i also means you cool one heatsink instead of two.
Which card and cable for three common NAS builds
Most DIY NAS builds fall into one of three shapes, and each has a clear answer. Use the drive count and the backplane connector to find yours, make sure your board has a free x8 slot (our NAS motherboard guide lists boards that do), then check our RAIDZ2 drive count guide to see what capacity that bay count gives you.
- Six to eight drives in a CS382 or similar SATA-port backplane: 9300-8i, two SFF-8643 forward breakouts, a 40 mm fan.
- Eight hard drives on a tight budget: 9207-8i with its bundled SFF-8087 breakouts, plus the fan.
- Twelve to sixteen bays on a direct-attach server backplane: 9400-16i and four SFF-8643 to SFF-8643 cables, or a 9300-8i on an expander backplane with one or two.
If you only need two to six more SATA ports on a small board, an HBA is overkill; a JMB585 or ASM1166 card from our SATA card comparison uses less power and fits an x4 or x1 slot. For a small, quiet box, our mini PC NAS build for TrueNAS or Unraid is a better starting point. Past that point, or the moment SAS drives or a Mini-SAS backplane enter the plan, the HBA is the right call, and the cable and fan are what make it work on day one.