Repository navigation
Description
Stride should support documented physical light units and calibrated camera exposure.
This can be achieved with automatic migration of existing assets, so equivalent behavior can be preserved.
This feature give artists a predictable relationship between lighting authored in DCC applications and lighting rendered in Stride.
Importers could convert documented quantities instead of relying on arbitrary intensity multipliers and manual adjustments.
For example, glTF already specifies candela for point and spot lights and lux for directional lights.
glTF specification
A defined lighting scale would also make it easier to validate Stride against offline reference renders from Mitsuba etc.
With matched geometry, materials, light distributions, and exposure, developers could compare direct lighting and material response quantitatively, then evaluate the errors introduced by real-time approximations.
This would help identify normalization bugs, prevent rendering regressions, and evaluate future lighting improvements.
The feature should document world scale, light normalization, color conventions, and exposure calibration. Existing scenes, prefabs, and compositor settings should receive versioned migrations, with clear guidance for scripts and custom shaders.
The suggested values below are examples for new content, not conversions of today’s Intensity = 1. Migration factors would be established through calibration.
| Light/source | Current Stride data | Suggested physical data | Example value | Editor presentation |
|---|---|---|---|---|
| Directional / sun | Unitless Intensity, default 1 |
Illuminance in lux | 100,000 lx |
Illuminance [100000] lx |
| Point | Unitless Intensity, default 1 |
Luminous intensity in candela; optional lumen input | 100 cd |
Intensity [100] [cd â–¾] |
| Spot | Unitless Intensity, default 1 |
Luminous intensity in candela; lumen conversion accounts for cone profile | 1,000 cd |
Intensity [1000] [cd â–¾], followed by cone settings |
| Area light — future feature | No standard built-in area light | Luminous flux in lumens, or luminance in cd/m² | 800 lm |
Output [800] [lm â–¾], with dimensions |
| Emissive material | Color/texture × relative intensity | Luminance in cd/m², also called nits | 200 cd/m² |
Emission luminance [200] cd/m² |
| Skybox / HDRI | Environment texture × intensity | Calibrated environment values plus a dimensionless gain | Calibrated HDRI, gain 1× |
Environment, Calibration, Gain [1] × |
| Ambient | Color × intensity | Keep as an artistic gain; use a calibrated uniform environment for physical ambient illumination | Gain 1× |
Ambient gain [1] × |
| Voxel GI | Intensity plus bounce/specular scales | Preserve the lighting scale through GI; retain dimensionless adjustment gains | Gain 1× |
Indirect lighting gain [1] × |
Candela for point/spot lights and lux for directional lights would align with glTF’s existing definitions.
Camera exposure
| Setting | Current Stride | Suggested data | Editor presentation |
|---|---|---|---|
| Manual exposure | Tone-map brightness adjustment in stops | Calibrated EV100, or equivalent photographic settings | Exposure input [EV100 / Camera settings] |
| Aperture | No photographic exposure input on camera | f-number, e.g. 16 |
Aperture [f/16] |
| Shutter speed | No photographic exposure input on camera | Seconds, e.g. 0.008 |
Shutter speed [1/125] s |
| Sensitivity | No photographic exposure input on camera | ISO, e.g. 100 |
ISO [100] |
| Exposure compensation | Existing exposure adjustment provides related behavior | Signed stops, e.g. +1 |
Compensation [+1.0] EV |
| Automatic exposure | Image-luminance-based adaptation | Calibrated metering with EV100 limits | Metering, Min/Max EV100, Adaptation speed |
EV100 and camera settings would be two ways to enter the same exposure, within one rendering system. Higher EV100 darkens a fixed scene; positive exposure compensation brightens it.
Interface and serialization
- Always display units beside values.
- Changing the unit dropdown converts the value while preserving light output.
- Store a documented canonical quantity per light type.
- Define 1 scene unit = 1 metre for physical lighting.
- Keep range/culling distance separate from emitter size.
- Upgrade old assets once through asset versions.
- Document migration requirements for scripts, animated properties, and custom shaders.
Further read:
https://google.github.io/filament/main/filament.html#lighting
https://google.github.io/filament/main/filament.html#imagingpipeline/physicallybasedcamera
Activity
icauro commentedon Oct 21, 2026
Also related issue #1262